HPI5-AT pH/Ion Meter

GENERAL FEATURES

  • Color High contrast LCD touchscreen, 7.0 inches.
  • Intelligent operation system provides features including user management, calibration management, method management, data management and etc.
  • Multi-reading feature allows auto-read, timed-read and continuous-read.
  • Automatic/Manual temperature compensation ensures accurate results.
  • Data Storage 1000 sets for each parameter (GLP-compliant).
  • Dat a analy s is f eat ur e helps us er r ev iew, c om par e and recalculate results.
  • Support for USB or RS-232 communication.
  • Reset feature automatically resumes all settings back to factory default options.
  • IP54 waterproof.

Ion

  • 1-6 points calibration
  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L,pX, ppm, ppb, etc.
  • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
  • Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO -, BF -,NH4  , K , Na , Ca  , Cu  , Pb  , Ag  and etc., user-defined method is supported.

pH

  • p1-6 points calibration with Standard Recognition.
  • Selectable pH buffer groups, including DIN, NIST, USA, MERK,JIS, GB.
  • Support for pH standard group customization.
  • Automatic electrode diagnosis with pH slope and offset display

Share with friends

Description

Model HPI5-AT
Parameters pH/ISE/Temp.(mV/ORP/pX)
 

 

 

pH

Range -2.000 to 20.000 pH
Resolution 0.1, 0.01, 0.001pH
Accuracy ±0.002 pH
Calibration Points Up to 6
Standard Customization Yes
Calibration Reminder Yes
Standard Recognition NIST, GB, DIN, USA, MERK, JIS buffers
Slope Limit Yes
 

 

mV/ORP

Range -2000.00 to 2000.00 mV
Resolution 0.1, 0.01 mV
Accuracy reading whichever is greater
EH ORP Mode Yes
ORP Calibration Points 1 custom point (relative mV)
 

pX

Range -2.000 to 20.000 pX
Resolution 0.1, 0.01, 0.001 pX
Accuracy ±0.002 pX
Calibration Points Up to 6
 

 

ISE

Range 1.000e-9 to 9.999e+9
Units mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution Up to 4 significant digits
Accuracy ±0.3%
Calibration Points Up to 6
 

Temperature

Range -10 to 135 ºC, 14 to 275 ºF
Unit ºC, ºF
Resolution 0.1
Accuracy ±0.1
 

Measurement

Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
 

Data management

Data Storage 1000 Groups
GLP Features Yes
Log Management Yes
Inputs pH Electrode BNC(Q9)
Temp. Probe 4-pin aviation connector
Outputs USB USB 2.0 flash memory device, PC, scanner
RS 232 printer, auto-sampler
 

Display options

Backlight Yes
Auto Shutdown 1~60 min, off
IP Rating IP54
Date and Time Yes
 

General

Power AC Adapter, 100-240V AC input, DC24V output
Dimensions 220×195×68 mm
Weight 950g (2.09 lb)